The following table shows a brief description of the variables appearing in this tab. The table also displays their default values and their generally acceptable range:
Variable |
Default Value |
Range |
|
||
○ Partition Coefficients (Ki) |
0.0 |
Positive |
○ Split % |
0.0 |
0-100 |
○ Light Phase Solvent Name |
<none> |
Any Pure Component |
○ Solubility in Light Phase (g/L) |
0.0 |
Positive |
○ Heavy Phase Solvent Name |
<none> |
Any Pure Component |
○ Solubility in Heavy Phase (g/L) |
0.0 |
Positive |
○ Common Solvent |
<none> |
Any Pure Component |
○ Fraction in Top (Light) Phase |
0.4 |
0-1 |
○ Product Component Name |
<none> |
Any Pure Component |
● Recovery Yield (%) |
0.0 |
0-100 |
Symbol Key: ○ User-specified value (always input); ● Calculated value (always output); ◙ Sometimes input, sometimes output
The following list describes the available specification choices in this tab; for more details on how these are implemented, see Batch Extraction / Phase Split: Modeling Calculations.
•Common solvent systems...
Common solvent systems (e.g., aqueous two-phase systems) are commonly used in biotechnology to recover and purify proteins and other biological molecules.